§ 7.9.5. Standards for Approval.  


Latest version.
  • A dock may be permitted subject to the following conditions:

    (A)

    A dock projection into a waterway, exclusive of dock pilings, shall be designed by one of the following methods:[Amd. Ord. 11-12 5/15/12]

    i.

    If no existing seawall: Five feet as measured from the water's edge at mean low tide. [Amd. Ord. 11-12 5/15/12]

    ii.

    If existing or proposed seawall without batter piles: Five feet as measured from the face of the seawall. [Amd. Ord. 11-12 5/15/12]

    iii.

    If existing or proposed seawall with or without a seawall cap with batter piles: Seven feet as measured from the face of the seawall. [Amd. Ord. 11-12 5/15/12]

    (B)

    When plot frontage exists along a body of water, only one dock is permitted. The dock shall not extend any closer than ten feet to the property line of adjacent property or the distance established for the side yard setback whichever is greater. [Amd. Ord. 40-95 8/8/95]

    (C)

    At least one ladder extending from the dock surface to two feet below the mean low waterline shall be provided for each dock. [Amd. Ord. 40-95 8/8/95]